Bard part 9010-089 is a precision orifice with a 1.40 mm (0.0551 inch) bore used to meter refrigerant flow in select Bard wall-mounted air conditioner and heat pump applications where the correct fixed restriction is critical to proper superheat, capacity, and overall system performance. As an OEM Bard replacement, this orifice is sized to match the original engineering specification, helping technicians restore correct refrigerant control after a restriction, contamination issue, or component replacement. Always verify the required orifice size against your unit model and serial number or the Bard service literature before ordering, since the correct metering size can vary by configuration.