logo
banner
Explore fractional-tonnage cabinet cooling at VoltAireCooling.com.
image
image image image

Bard 9022-094 - R7184A Primary Control

Bard part number 9022-094 is an OEM primary control used to manage safe burner operation in Bard equipment that uses a Honeywell R7184A style interrupted-ignition oil primary control. This control is designed to coordinate the call for heat sequence, power the burner motor and ignitor, monitor flame through a cad cell input, and lock out on a fault condition to help prevent unsafe operation. If your unit is failing to light consistently, tripping on safety, or showing nuisance lockouts, replacing a known-failing primary control with the correct Bard-specified 9022-094 is a dependable way to restore proper start up and safety timing while maintaining factory-correct wiring and operation.


  • Technical Specifications
  • Product number: 9022-094
  • Manufacturer description: R7184A Primary Control
  • Weight: 2.000 lbs
  • HTS Code: "9032.10.0030"

  • Previous Versions
  • 9022-056 (Obsolete, superseded by 9022-094)
  • 9022-005 (Obsolete, superseded by 9022-056)

$225.00