Bard part number 9048-103 is an OEM primary control (R8184M) used on oil-fired Bard heating equipment to manage burner start and safety shutoff based on a low-voltage call for heat while monitoring flame through a cad cell sensor. This control includes an integral low-voltage transformer and a manual reset safety lockout, helping protect the system if ignition does not establish within the safety timing, and it is designed to mount on a standard 4 x 4 junction box or directly on the burner. If you are replacing a failed or nuisance-tripping primary control, confirm the exact R8184M model and wiring terminals in your Bard service literature to ensure proper compatibility with the burner motor, ignition, oil valve, and thermostat connections.
Manufacturer description: Primary Control R8184M B1810613
Replacement part number: No Longer Available
Please call for available options or find replacement parts.
(844) WALLMOUNT (844-925-5668)